Mecer 1000VA ON-LINE UPS (ME-1000-WPTU)
About this item
- Mecer Winner Pro 1kVA 800W Pf 0.8 On-Line Tower UPS
- True double-conversion online UPS
- Wide input voltage range (110-300 VAC)
- Input power factor correction 0.99
- Output power factor 0.8
- Converter mode available
- Generator compatible
- Adjustable battery numbers only available for 6K and up models
Specifications and features
|
|
| Product | ME-1000-WPTU UPS |
| CAPACITY | 1000 VA / 800 W |
| PHASE | Single phase with ground |
| INPUT | |
| Input Voltage Range | 55-150 VAC or 110-300 VAC (Based on load at 50%); 85-140VAC or 160-280VAC (Based on load at 100%) |
| Nominal Voltage | 100/110/115/120/127VAC or 200/208/220/230/240VAC |
| Frequency Range | 40Hz ~70 Hz |
| Power Factor | >= 0.99 @ Nominal Voltage (100% load) |
| OUTPUT | |
| Voltage Regulation | ± 1% |
| Output Voltage | 100/110/115/120/127VAC or 200/208/220/230/240VAC |
| Frequency Range (Batt. Mode) | 50 Hz ± 0.25 Hz or 60 Hz ± 0.3 Hz |
| Transfer Time : AC Mode to Battery Mode | Zero |
| Transfer Time : Inverter to Bypass | 4 ms (Typical) |
| Transfer Time : Waveform (Batt. Mode) | Pure Sine Wave |
| Current Crest Ratio | 3::1 |
| Harmonic Distortion | <=3% THD (Linear Load); <= 6% THD (Non-linear Load) |
| Frequency Range (Synchronized Range) | 47~53 Hz or 57~63 Hz |
| EFFICIENCY | |
| Battery Mode | 0.83 |
| AC Mode | 0.88 |
BATTERY |
|
| Long-run Model : Battery Type | Depending on the capacity of external batteries |
| Long-run Model : Charging Current (max.) | 1A/2A/4A/6A (Adjustable) |
| Long-run Model : Charging Voltage | 27.4 VDC ± 1%, 41.0 VDC ± 1% |
| Long-run Model : Numbers | 2, 3 |
| Standard Model : Battery Type | 12 V / 9 AH |
| Standard Model : Charging Current (max.) | 1A |
| Standard Model : Charging Voltage | 27.4 VDC ± 1% |
| Standard Model : Numbers | 2 |
| Standard Model : Typical Recharge Time | 4 hours recover to 90% capacity |
| INDICATORS | |
| LCD | Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators |
| ALARM | |
| Battery Mode | Sounding every 4 seconds |
| Low Battery | Sounding every second |
| Overload | Sounding twice every second |
| Fault | Continuously sounding |
| ENVIRONMENT | |
| Operating Humidity | 20~90% RH @ 0- 40°C (non-condensing) |
| Noise Level | Less than 50dB @ 1 Meter |
| PHYSICAL | |
| Standard Model : Dimension, D x W x H (mm) | 282 x 145 x 220 |
| Standard Model : Net Weight (kgs) | 9.8 |
| Long-run Model : Dimension, D x W x H (mm) | 282 x 145 x 220 |
| Long-run Model : Net Weight (kgs) | 4.1 |
| MANAGEMENT | |
| Optional SNMP | Power management from SNMP manager and web browser |
| Smart RS-232/USB | Supports Windows 2000/2003/XP/Vista/2008, Windows 7/8/10, Linux, and MAC |





Reviews