MECER 10KVA/10KW, 3P/3P, 3U Rack
Features
• True double-conversion online UPS
• Wide input voltage range (110-300 VAC)
• Input power factor correction 0.99
• Output power factor 0.8
• Converter mode available
• ECO mode operation for energy saving (only available for 1-3KVA)
• Generator compatible
• Adjustable battery numbers only available for 6K and up models
• Smart SNMP works well with either USB or RS-232 together
• Emergency power-off function only available for 6K and up models
MECER 10KVA/10KW, 3P/3P, 3U Rack, WITHOUT BATTERY
input 360VAC/380VAC/400VAC/415VAC (3Ph+N+PE)
output 360VAC/380VAC/400VAC 415VAC (3Ph+N),
default output 400VAC,
W/ CD, USB cable, RS-232 cable and Mounting ears with connector box and Parallel kit.
Mecer 10KVA Online Smart-UPS specifications
- Capacity: 10KVA (10,000VA)
- Technology: Online double conversion
- Input Voltage: 380V/400V/415V (3-phase)
- Input Voltage Range: ±25% (adjustable)
- Output Voltage: 380V/400V/415V (3-phase)
- Output Voltage Regulation: ±1%
- Frequency: 50/60Hz (auto-sensing)
- Output Power Factor: 0.9
- Crest Factor: 3:1
- Efficiency: ≥ 90%
- Transfer Time: 0ms (online mode)
- Battery Type: Sealed lead-acid
- Battery Quantity: External battery packs supported
- Battery Voltage: 240V DC
- Recharge Time: < 7 hours to 90% capacity
- Communication Interface: RS-232, USB, SNMP (optional)
- Display: LCD display panel
- Audible Alarms: Battery mode, low battery, overload, fault
- Protection: Overload, short circuit, over-temperature, input/output over-voltage, input/output under-voltage, battery low voltage, surge
- Operating Temperature: 0°C to 40°C
- Storage Temperature: -15°C to 45°C
- Humidity: 0% to 95% (non-condensing)
- Dimensions: 430mm x 192mm x 355mm
- Weight: 38kg
- Certification: CE, ISO9001
Specifications and features | |
Product Code | ME-10000-WPTU |
CAPACITY | 10000 VA / 8000 W |
PHASE | Single phase with ground |
INPUT | |
Input Voltage Range | 110-300 VAC (Based on load at 50%); 176-300 VAC (Based on load at 100%) |
Nominal Voltage | 208/220/230/240 VAC |
Frequency Range | 46~54 Hz or 56~64 Hz |
Power Factor | >= 0.99 @ Nominal Voltage (100% load) |
OUTPUT | |
Voltage Regulation | ± 1% |
Output Voltage | 208/220/230/240 VAC |
Frequency Range (Batt. Mode) | 50 Hz or 60 Hz ± 0.1 Hz |
Transfer Time : AC Mode to Battery Mode | Zero |
Transfer Time : Inverter to Bypass | Zero |
Transfer Time : Waveform (Batt. Mode) | Pure Sine Wave |
Current Crest Ratio | 3::1 |
Harmonic Distortion | <= 3% THD (Linear Load); <= 5% THD (Non-linear Load) |
Frequency Range (Synchronized Range) | 46~54 Hz or 56~64 Hz |
EFFICIENCY | |
Battery Mode | 0.91 |
AC Mode | 0.93 |
BATTERY | |
Long-run Model : Battery Type | Depending on the capacity of external batteries |
Long-run Model : Charging Current (max.) | 1A/2A/4A/6A (Adjustable, 6A is only available for 16pcs batteries) |
Long-run Model : Charging Voltage | 273 VDC ± 1% (Based on 20pcs bateries) |
Long-run Model : Numbers | 16~20 (Adjustable) |
Standard Model : Battery Type | 12 V / 9 Ah |
Standard Model : Charging Current (max.) | 1A/2A |
Standard Model : Charging Voltage | 218.4 VDC ± 1%, 273 VDC ± 1% |
Standard Model : Numbers | 16, 20 |
Standard Model : Typical Recharge Time | 9 hours recover to 90% capacity |
INDICATORS | |
LCD | Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators |
ALARM | |
Battery Mode | Sounding every 4 seconds |
Low Battery | Sounding every second |
Overload | Sounding twice every second |
Fault | Continuously sounding |
ENVIRONMENT | |
Operating Humidity | 0~95% RH @ 0- 40°C (non-condensing) |
Noise Level | Less than 58dB @ 1 Meter |
PHYSICAL | |
Standard Model : Dimension, D x W x H (mm) | 442 x 190 x 688 |
Standard Model : Net Weight (kgs) | 66, 76 |
Long-run Model : Dimension, D x W x H (mm) | 442 x 190 x 318 |
Long-run Model : Net Weight (kgs) | 16 |
MANAGEMENT | |
Optional SNMP | Power management from SNMP manager and web browser |
Smart RS-232/USB | Supports Windows 2000/2003/XP/Vista/2008, Windows 7/8/10, Linux, and MAC |