Mecer 6000VA (6KVA)On-Line Tower UPS (ME-6000-WPTU) description
Overview
Mecer 6000VA On-Line Tower UPS (ME-6000-WPTU) – Capacity: 6000 VA / 4800 W, Battery Type: 12 V / 9 Ah, Frequency Range: 46~54 Hz or 56-64 Hz, Includes AVR, Monitoring Software, Built-in Surge Protection, Black Colour.
The Mecer 6000VA (6KVA) On-Line Tower UPS (ME-6000-WPTU) is a high-performance uninterruptible power supply system designed to provide reliable power protection for critical electronic equipment.
Features
- Impressive Capacity: With a robust 6KVA (6000VA) capacity, this UPS can support a wide range of power-hungry devices and servers, ensuring they remain operational during power fluctuations and outages.
- Extended Runtime Options: The ME-6000-WPTU offers expandable battery options to extend runtime during prolonged outages, giving you ample time to safely shut down your equipment or ride out temporary power interruptions.
- User-Friendly LCD Display: The built-in LCD display provides real-time information on power status, battery capacity, load level, and other critical metrics, making it easy to monitor the UPS’s performance and troubleshoot issues.
Specifications
Type
Mecer Online Tower UPS
Phase
Single phase with ground
Capacity
6000 VA / 4800 W
Input
Voltage Range
Low Line Transfer
176 VAC ± 3% @ 100% load, 110 VAC ± 3% 50% load
Low Line Comeback
186 VAC ± 3% @ 100% load, 120 VAC ± 3% @ 50% load
High Line Transfer
300 VAC ± 3%
High Line Comeback
290 VAC ± 3%
Frequency Range
46~54 Hz or 56-64 Hz
Power Factor
≥ 0.99 @ 100% load
Output
Output Voltage
208/220/230/240 VAC
AC Voltage Regulation (Batt. Mode)
± 1%
Frequency Range (Synchronised Range)
46 ~ 54 Hz or 56 ~ 64 Hz
Frequency Range (Batt. Mode)
50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Current Crest Ratio
3:1
Harmonic Distortion
≤ 3 % THD (Linear Load), ≤ 5 % THD (non-linear load)
Transfer Time
AC Mode to Batt. Mode
Zero
Inverter to Bypass
Zero
Waveform (Batt. Mode)
Pure Sinewave
Efficiency
AC Mode
92%
Battery Mode
90%
Battery
Battery Type
12 V / 9 Ah
Numbers
16
Typical Recharge Time
9 hours to recover to 90% capacity
Charging Current (max.)
1.0 A / 2.0 A (adjustable)
Charging Voltage
218.4 VDC ± 1%
Indicators
LCD Panel
UPS status, Load level, Battery level, Input/output Voltage, Discharge timer and Fault Conditions
Alarm
Battery Mode
Sounding every 4 seconds
Low Battery
Sounding every second
Overload
Sounding twice every second
Fault
Continuously sounding
Physical
Dimension, D x W x H (mm)
369Â x 190 x 668
Net Weight (kgs)
61
Environment
Humidity
0-95 % RH @ 0-50°C (non-condensing)
Noise Level
Less than 55dB @ 1 Meter
Management
Smart RS-232/USB
Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix and Mac
Optional SNMP
Power management from SNMP manager and web browser
Reviews