Mecer 6000VA (6KVA)On-Line Tower UPS (ME-6000-WPTU) description
Overview
Mecer 6000VA On-Line Tower UPS (ME-6000-WPTU) – Capacity: 6000 VA / 4800 W, Battery Type: 12 V / 9 Ah, Frequency Range: 46~54 Hz or 56-64 Hz, Includes AVR, Monitoring Software, Built-in Surge Protection, Black Colour.
The Mecer 6000VA (6KVA) On-Line Tower UPS (ME-6000-WPTU) is a high-performance uninterruptible power supply system designed to provide reliable power protection for critical electronic equipment.
Features
- Impressive Capacity: With a robust 6KVA (6000VA) capacity, this UPS can support a wide range of power-hungry devices and servers, ensuring they remain operational during power fluctuations and outages.
- Extended Runtime Options: The ME-6000-WPTU offers expandable battery options to extend runtime during prolonged outages, giving you ample time to safely shut down your equipment or ride out temporary power interruptions.
- User-Friendly LCD Display: The built-in LCD display provides real-time information on power status, battery capacity, load level, and other critical metrics, making it easy to monitor the UPS’s performance and troubleshoot issues.
Specifications
Type
Mecer Online Tower UPS
Phase
- Single phase with ground
Capacity - 6000 VA / 4800 W
Input
Voltage Range
Low Line Transfer - 176 VAC ± 3% @ 100% load, 110 VAC ± 3% 50% load
Low Line Comeback - 186 VAC ± 3% @ 100% load, 120 VAC ± 3% @ 50% load
High Line Transfer - 300 VAC ± 3%
High Line Comeback - 290 VAC ± 3%
Frequency Range - 46~54 Hz or 56-64 Hz
Power Factor - ≥ 0.99 @ 100% load
Output
Output Voltage - 208/220/230/240 VAC
AC Voltage Regulation (Batt. Mode)
± 1%
Frequency Range (Synchronised Range) - 46 ~ 54 Hz or 56 ~ 64 Hz
Frequency Range (Batt. Mode) - 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Current Crest Ratio - 3:1
Harmonic Distortion - ≤ 3 % THD (Linear Load), ≤ 5 % THD (non-linear load)
Transfer Time
AC Mode to Batt. Mode - Zero
Inverter to Bypass - Zero
Waveform (Batt. Mode) - Pure Sinewave
Efficiency
AC Mode - 92%
Battery Mode - 90%
Battery
Battery Type - 12 V / 9 Ah
Numbers - 16
Typical Recharge Time - 9 hours to recover to 90% capacity
Charging Current (max.) - 1.0 A / 2.0 A (adjustable)
Charging Voltage - 218.4 VDC ± 1%
Indicators
LCD Panel - UPS status, Load level, Battery level, Input/output Voltage, Discharge timer and Fault Conditions
Alarm
Battery Mode - Sounding every 4 seconds
Low Battery - Sounding every second
Overload - Sounding twice every second
Fault - Continuously sounding
Physical
Dimension, D x W x H (mm) - 369Â x 190 x 668
Net Weight (kgs) - 61
Environment
Humidity - 0-95 % RH @ 0-50°C (non-condensing)
Noise Level - Less than 55dB @ 1 Meter
Management
Smart RS-232/USB - Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix and Mac
Optional SNMP - Power management from SNMP manager and web browser