Mercury 10KVA UPS, 10000KVA Online UPS Specifications and details
he Mercury 10KVA Online UPS is a high-performance uninterruptible power supply designed to provide reliable power backup for critical systems. With a capacity of 10,000 VA , it ensures consistent and uninterrupted power, even during power outages or fluctuations. This UPS offers online double-conversion technology, which delivers pure sine wave output. Providing optimal protection for sensitive equipment. Ideal for use in data centers, servers, telecommunications, and industrial applications. The Mercury 10KVA Online UPS helps maintain operational continuity and safeguard devices from electrical disturbances.
The power rating of the 10kVA Mercury Online 3-Phase-in UPS is 9kW
Specifications
Output | : |
Phase | 1 Phase 4 Wire (3ph+N) |
Rated Voltage | 380 / 400 / 415VAC |
Rated Power Factor | 0.9 |
Frequency | 50Hz/60Hz ±0.5Hz (Battery Mode) 50/60 (1±1/2/4/5%)Hz (On-Line) |
Voltage Precision | Output Balanceable:±1.0%; Output Non-Balanceable:±3.0% |
THD | Linear Load: ≤2.0%; Non-Linear Load: ≤4.5% |
Overload Capability | 110% for 60mins; 125% for 10mins; 150% for 1min |
Crest Factor | ≥3 : 1 |
Waveform | Sine Wave |
DC Component | ≤500mVDC |
Output Current | 24A / 36A / 48A / 72A / 96A (380V – Full Load) 23A / 35A / 46A / 70A / 94A (400V – Full Load) 22A / 33A / 44A / 66A / 88A (415V – Full Load) |
Input | : |
Rated Voltage | 192 / 216 / 240VAC |
Voltage Range | Po≤69%: 208±5VAC~478±5VAC Po≥69%: 304±5VAC~478±5VAC |
Frequency | 40±0.5Hz~70±0.5Hz |
Input Phase | 3 Phase 4 Wire (3ph+N) |
THDi | Input THD≤1.0%, Linear Load: ≤3.0% Input THD≤1.0%, Non-Linear Load: ≤7.0% |
Power Factor | >0.99 |
Battery | : |
Model | Sealed Lead Acid Battery (VRLA) |
Configurable Battery | 32 pcs (Not included; purchased separately) |
Discharge Current (320VDC) | 54A / 81A / 106A / 160A / 213A |
Charge Current (Max) | 20/30KVA 40/60/80KVA 15A 30A |
System |
: |
Efficiency | ≥90% (Line Mode) ≥93% 20/30KVA , ≥94% 40/60/80KVA (Battery Mode) ≥97% (ECO Mode) |
Wasting | ≤3% (Line Mode) ≤2% (ECO) |
Noise at 1M | <56dB |
Running Temperature | 0~40˚C |
Relative Humidity | 0%RH~95%RH (Non-condensing) |
Altitude | 1000m Output Normal Power |
Display | LCD+LED |
Breaker/ Fuse | 40A / 63A / 80A / 125A / 160A |
Remote Signaling | Dry Contact |
Communication | RS232/RS485/SNMP |
MTBF | Inverter MTBF >50,000 Hours Single Modules MTBF >250,000 Hours 1+1 Expandable Modules MTBF >400,000 Hours |
MTTR | The MTTR of Each Single UPS Modules is Lower 30mins |
Dielectric Resistance | > 2MΩ (500VDC) |
Dielectric Strength | 2820VDC, Leak Current<3.5mA, 1min |
Vibration Impact | Fulfill standard ISTA (International Safe Transmission Association) 1B |
Transportation | Fulfill standard ISTA (International Safe Transmission Association) 1B |
Degree Of Protection | Ip20 |
Net/Gross Weight (kg) | 215/239 |
Dimension(WxDxH) mm | 930 x 700 x 1390 |
Bypass | : |
Voltage Range | 380V 208/266/304±5VAC~399/418/437/475±5VAC 400V 220/280/320±5VAC~420/440/460±5VAC 415V 228/290/332±5VAC~436/457/477±5VAC |
Frequency Range | 50(1±10%)Hz / 60(1±10%)Hz |
Phase | 3 Phase 4 Wire (3ph+N) |
Overload Capability | 125%~170% for 10mins |
Eco Mode | : |
Voltage Range | 380V 304±5VAC~399 / 418±5VAC 400V 320±5VAC~420 / 440±5VAC 415V 332±5VAC~436 / 457±5VAC |
Frequency Range | 50(1±10%)Hz / 60(1±10%)Hz |
Phase | 3 Phase 4 Wire (3ph+N+PE) |
Model | EP10K |
Capacity | 10KVA |
Power | 9KW |
Maximum Input Current | 40A / 63A / 80A / 125A / 160A |