Specifications
Output | : |
Phase | 3 Phase 4 Wire (3ph+N+PE) |
Rated Voltage | 380 / 400 / 415VAC |
Rated Power Factor | 0.9 |
Frequency | 50Hz/60Hz ±0.5Hz (Battery Mode) 50/60 (1±1/2/4/5%)Hz (On-Line) |
Voltage Precision | Output Balanceable:±1.0%; Output Non-Balanceable:±3.0% |
THD | Linear Load: ≤2.0%; Non-Linear Load: ≤4.5% |
Overload Capability | 110% for 60mins; 125% for 10mins; 150% for 1min |
Crest Factor | ≥3 : 1 |
Waveform | Sine Wave |
DC Component | ≤500mVDC |
Output Current | 24A / 36A / 48A / 72A / 96A (380V – Full Load) 23A / 35A / 46A / 70A / 94A (400V – Full Load) 22A / 33A / 44A / 66A / 88A (415V – Full Load) |
Input | : |
Rated Voltage | 380 / 400 / 415VAC |
Voltage Range | Po≤69%: 208±5VAC~478±5VAC Po≥69%: 304±5VAC~478±5VAC |
Frequency | 40±0.5Hz~70±0.5Hz |
Input Phase | 3 Phase 4 Wire (3ph+N+PE) |
THDi | Input THD≤1.0%, Linear Load: ≤3.0% Input THD≤1.0%, Non-Linear Load: ≤7.0% |
Power Factor | >0.99 |
Battery | : |
Model | Sealed Lead Acid Battery (VRLA) |
Configurable Battery | 32 (Not included, purchased separately) |
Discharge Current (320VDC) | 54A / 81A / 106A / 160A / 213A |
Charge Current (Max) | 20/30KVA 40/60/80KVA 15A 30A |
System |
: |
Efficiency | ≥90% (Line Mode) ≥93% 20/30KVA , ≥94% 40/60/80KVA (Battery Mode) ≥97% (ECO Mode) |
Wasting | ≤3% (Line Mode) ≤2% (ECO) |
Noise at 1M | <56dB |
Running Temperature | 0~40˚C |
Relative Humidity | 0%RH~95%RH (Non-condensing) |
Altitude | 1000m Output Normal Power |
Display | LCD+LED |
Breaker/ Fuse | 40A / 63A / 80A / 125A / 160A |
Remote Signaling | Dry Contact |
Communication | RS232/RS485/SNMP |
MTBF | Inverter MTBF >50,000 Hours Single Modules MTBF >250,000 Hours 1+1 Expandable Modules MTBF >400,000 Hours |
MTTR | The MTTR of Each Single UPS Modules is Lower 30mins |
Dielectric Resistance | > 2MΩ (500VDC) |
Dielectric Strength | 2820VDC, Leak Current<3.5mA, 1min |
Vibration Impact | Fulfill standard ISTA (International Safe Transmission Association) 1B |
Transportation | Fulfill standard ISTA (International Safe Transmission Association) 1B |
Degree Of Protection | Ip20 |
Net/Gross Weight (kg) | 242/266 |
Dimension(WxDxH) mm | 930 x 700 x 1390 |
Bypass | : |
Voltage Range | 380V 208/266/304±5VAC~399/418/437/475±5VAC 400V 220/280/320±5VAC~420/440/460±5VAC 415V 228/290/332±5VAC~436/457/477±5VAC |
Frequency Range | 50(1±10%)Hz / 60(1±10%)Hz |
Phase | 3 Phase 4 Wire (3ph+N+PE) |
Overload Capability | 125%~170% for 10mins |
Eco Mode | : |
Voltage Range | 380V 304±5VAC~399 / 418±5VAC 400V 320±5VAC~420 / 440±5VAC 415V 332±5VAC~436 / 457±5VAC |
Frequency Range | 50(1±10%)Hz / 60(1±10%)Hz |
Phase | 3 Phase 4 Wire (3ph+N) |
Model | EP20K |
Capacity | 20kVA |
Power | 18KW |
Maximum Input Current | 40A / 63A / 80A / 125A / 160A |