Giganet GN-UPS-15KVAS-RT Single Phase (VRLA) UPS
The GIGANET GN-UPS-15KVAS-RT is a high‑reliability single-phase UPS designed for smaller installations, office equipment, small server rooms, networking setups, or home/office backup power needs. Using a VRLA (Valve-Regulated Lead-Acid) battery design, this UPS provides dependable, maintenance‑free battery backup to protect against outages, surges, and power instability.
The UPS is built for simplicity and reliability, offering a balance of capacity, backup runtime, and ease of maintenance. The VRLA battery technology reduces the need for regular upkeep while providing sufficient runtime for safe shutdowns, hardware protection, or short‑duration power bridging.
Specifications
| Model | GN-UPS-15KVAS-RT | GN-UPS-20KVAS-RT | ||
| Capacity VA/Watts | 15000VA/15000WA | 20000VA/20000WA | ||
| INPUT | ||||
| Nominal voltage | 220/230/240Vac,(L+N+PE) | |||
| Operating voltage range | 208~478Vac | |||
| Operating frequency range | 40~70Hz | |||
| Power factor | ≥0.99 | |||
| Harmonic distortion (THDi) | 3% (100% non-linear load) | |||
| Bypass voltage range | Max. voltage:220V: +25%(optional +10%,+15%,+20% ) ; 230V: +20%(optional +10%,+15% ) ;240V: +15%(optional +10%)
Min. voltage: -45% (optional -20%,-30%) |
|||
| Bypass Frequency range | Frequency protection range: ±10% | |||
| Generator input | Support | |||
OUTPUT |
||||
| Output Voltage | 220/230/240Vac,(L+N+PE) | |||
| Voltage regulation | 1.0 | |||
| Power factor | ±1% | |||
| Output frequency | Line mode | ±1%/±2%/±4%/±5%/±10% of the rated frequency(optional) | ||
| Bat. mode | (50/60±0.2%)Hz | |||
| Crest factor | 3:1 | |||
| Harmonic Distortion (THDv) | ≤2% Linear load≤5% Non linear load | |||
| Effeciency | UP to 94.5% | UP to 95.0% | ||
| BATTERY | ||||
| Battery Voltage | ±180/192/204/216/228/240/252/264/276/288/300Vdc(30/32/34/36/38/40/42/44/46/48/50pcs optional) | |||
| (charge current can be set according to battery capacity installed) | Max. current 18A | Max. current 20A | ||
SYSTEM FEATURES |
||||
|
Overload |
Line Mode | Load≤110%: last 60min, ≤125%: last 10min, ≤150%: last 1min, ≥150% turn to bypass mode immediately | ||
| Bat. Mode | Load≤110%: last 10min, ≤125%: last 1min, ≤150%: last 5S, ≥150% shut down UPS immediately | |||
| Bypass Mode | Breaker( Load < 125%, long-term operation) | |||
| Short circuit | Hold whole system | |||
| Communication interface | RS232, RS485, Parallel, Intelligent Slot(SNMP card/ Relay card(optional)), | |||
| BMS (optional),EPO port, Output port, MAINTAIN-AUXSWS | ||||
| Dimension W×D×H | 443×131(3U)x580 mm | |||
| Net weight | 31kg | 32kg | ||
| ENVIRONMENT | ||||
| Operating temperature | 0℃~40℃ | |||
| Storage temperature | -25℃~55℃ | |||
| Humidity range | 0~95%RH (Non condensing) | |||
| Altitude | <1500m | |||
| Noise level | <55dB | <58dB | ||
| STANDARDS | ||||
| Safety | IEC/EN62040-1,IEC/EN60950-1 | |||
| EMC | IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4- 5,IEC61000-4-6,IEC61000-4-8 | |||