Giganet GN-UPS-LI-850VA Line Interactive 850VA UPS
The GIGANET GN-UPS-LI-850VA is a compact, line-interactive UPS that delivers reliable power backup and voltage regulation for home offices, small businesses, or network setups. With an 850 VA / 480 W capacity, this unit is ideal for powering desktops, routers, modems, small servers, POS systems, network switches, and other essential electronics — especially in areas with shaky or fluctuating mains power.
Features |
| Line Interactive UPS with simulated sinewave output |
| Excellent microprocessor control guarantees high reliability(Internal self-diagnostic technology) |
| Boost and buck AVR for voltage stabilization (wide input range with two boost and one buck control) |
| Auto restart while AC is recovering |
| Cold start function |
| Off-mode charging |
| Fast intelligent battery recharge function |
| Generator compatible |
| Offering LED and LCD panels for selections |
| Easy installation and operation with compact size |
| Ideally applicable for PC, Workstations, TVs, POS devices etc. |
| Optional USB/RS232 communication port and RJ11/RJ45 protection |
Specifications
| Model | GN-UPS-LI-650VA | GN-UPS-LI-850VA | GN-UPS-LI-1000VA | GN-UPS-LI-1200VA |
| Capacity VA/Watts | 650 / 360 | 850 / 480 | 1000 / 600 | 1200 / 720 |
| INPUT | ||||
| Voltage | 220/230/240Vac | |||
| Voltage range | 140~300Vac | |||
| Frequency Range | 50/60Hz (auto sensing) | |||
| OUTPUT | ||||
| AC Voltage Regulation (Batt. Mode) | ±10% | |||
| Frequency Range (Batt. Mode) | 50/60Hz ±1 Hz | |||
| Transfer Time | Typical 4-8ms, 13ms Max. | |||
| Waveform (Batt. Mode) | Simulated Sinewave | |||
| BATTERY | ||||
| Battery Voltage | 12Vdc | 24Vdc | ||
| Battery Type & Number | 12 V /7Ah x 1 | 12 V /9Ah x 1 | 12 V /7Ah x 2 | 12 V /9Ah x 2 |
| Max charger current (A) | 4~6 hours recover to 90% capacity | 6~8 hours recover to 90% capacity | ||
| INDICATORS | ||||
| LED Display (LED version) | AC Mode, Battery Mode, Overload, Fault | |||
| LCD Display (LCD version) | AC Mode, Battery Mode, Load Level, Battery Level, Input Voltage, Output Voltage, Overload, Fault, and Battery Low | |||
| PROTECTION | ||||
| Full Protection | Short circuit, Overload , Overcharge and overdischarge protection | |||
| ALARM | ||||
| Battery mode | Sounding every 10 seconds | |||
| Low Battery | Sounding every second | |||
| Overload | Sounding every 0.5 second | |||
| Battery Replacement Alarm | Sounding every 2 seconds | |||
| Fault | Continuously sounding | |||
| MANAGEMENT | ||||
| Communication port | USB or RS232(Supports Windows 2000/2003/XP/Vista/2008, Windows 7, Linux, Unix, and MAC) | |||
| OPERATING ENVIRONMENT | ||||
| Humidity | 0-90 % RH @ 0- 40°C (non-condensing) | |||
| Noise Level | Less than 45dB | |||
| PHYSICAL | ||||
| Dimensions WxDxH (mm) | 289*101*142 | 314*130*175 | ||
| Weight (Kgs) | 4.3 | 4.9 | 7.2 | 7.8 |
| STANDARDS | ||||
| Safety | I EC/EN62040-1, IE C/EN60950-1 | |||
| EMC | I EC/EN62040-2, I EC61000-4-2,1EC61000-4-3,IEC61000-4-4,1EC61000-4-5,IEC61000-4-6, I EC61000-4-8 | |||