ME-2000-WPRU Mecer 2000VA / 1600W ON-LINE UPS Rack Mount 2U description
Overview
Mecer 2000VA / 1600W 2U ON-LINE SINE WAVE Rackmountable UPS (with Monitoring Software) -Black. 2000 VA / 1600 W, Pure Sine Wave, 12 V / 9 Ah batteries x4, Voltronic Power Winner Pro Online pure sine wave UPS. *6 month warranty on battery© Respective owners and brand holders. © 2023 ComXpert International CC. The contents has been generated by ComXpert International CC (//www.comx-computers.co.za). All products are sourced locally in South Africa and the warranty is that of the local supplier only. E&OE.
Product Highlights
- True double-conversion online UPS
- Wide input voltage range (110-300 VAC)
- Input power factor correction 0.99
- Output power factor 0.8
- Converter mode available
- ECO mode operation for energy saving (only available for 1-3KVA)
- Hot-swappable battery design only available for 1-3KVA
- Generator compatible
- Adjustable charging current via LCD or software (1A ~ 6A)
Specifications and features
GENERAL
- Product Code : ME-2000-WPRU
- CAPACITY 2000 VA / 1600 W
- PHASE Single phase with ground
INPUT
- Input Voltage Range 55-150 VAC or 110-300 VAC (Based on load at 50%); 85-140VAC or 160-280VAC (Based on load at 100%)
- Nominal Voltage 100/110/115/120/127VAC or 200/208/220/230/240VAC
- Frequency Range 40Hz ~70 Hz
- Power Factor >= 0.99 @ Nominal Voltage (100% load)
OUTPUT
- Voltage Regulation ± 1%
- Output Voltage 100/110/115/120/127VAC or 200/208/220/230/240VAC
- Frequency Range (Batt. Mode) 50 Hz ± 0.25 Hz or 60 Hz ± 0.3 Hz
- Transfer Time : AC Mode to Battery Mode Zero
- Transfer Time : Inverter to Bypass 4 ms (Typical)
- Transfer Time : Waveform (Batt. Mode) Pure Sine Wave
- Current Crest Ratio 3::1
- Harmonic Distortion — 3% THD (Linear Load); — 6% THD (Non-linear Load)
- Frequency Range (Synchronized Range) 47~53 Hz or 57~63 Hz
BATTERY
- Long-run Model : Battery Type Depending on the capacity of external batteries
- Long-run Model : Charging Current (max.) 1A/2A/4A/6A (Adjustable)
- Long-run Model : Charging Voltage 54.7 VDC ± 1%, 82.1 VDC ± 1%, 109.4VDC ±1%
- Long-run Model : Numbers 4, 6, 8
- Standard Model : Battery Type 12 V / 9 AH
- Standard Model : Charging Current (max.) 1A
- Standard Model : Charging Voltage 54.7 VDC ± 1%
- Standard Model : Numbers 4
- Standard Model : Typical Recharge Time 4 hours recover to 90% capacity
INDICATORS
- LCD Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators
ENVIRONMENT
- Operating Humidity 20~90% RH @ 0- 40°C (non-condensing)
- Noise Level Less than 50dB @ 1 Meter
PHYSICAL
- Standard Model : Dimension, D x W x H (mm) 410 x 438 x 88 [2U]
- Standard Model : Net Weight (kgs) 19
- Long-run Model : Dimension, D x W x H (mm) 410 x 438 x 88 [2U]
- Long-run Model : Net Weight (kgs) 12
Reviews