Mecer 10KVA Online Smart-UPS specifications
Overview
- Mercer Brand and manufacturer
- True double-conversion on line UPS
- DSP technology guarantees high reliability
- Output power factor 0.8
- Wide input voltage range (110-300 VAC)
- Input power factor correction 0.99
- 50Hz/60Hz frequency converter mode
- ECO mode operation for energy saving
- Emergency power off function (EPO)
- 3-stage extendable charging design for optimized battery performance
- Maintenance bypass available
- External battery bank is available as optional
Specifications
Specifications and features | |
Product | ME-10000-WPTU Smart-UPS |
CAPACITY | 10000 VA / 8000 W |
PHASE | Single phase with ground |
INPUT | |
Input Voltage Range | 110-300 VAC (Based on load at 50%); 176-300 VAC (Based on load at 100%) |
Nominal Voltage | 208/220/230/240 VAC |
Frequency Range | 46~54 Hz or 56~64 Hz |
Power Factor | >= 0.99 @ Nominal Voltage (100% load) |
OUTPUT | |
Voltage Regulation | ± 1% |
Output Voltage | 208/220/230/240 VAC |
Frequency Range (Batt. Mode) | 50 Hz or 60 Hz ± 0.1 Hz |
Transfer Time : AC Mode to Battery Mode | Zero |
Transfer Time : Inverter to Bypass | Zero |
Transfer Time : Waveform (Batt. Mode) | Pure Sine Wave |
Current Crest Ratio | 3::1 |
Harmonic Distortion | <= 3% THD (Linear Load); <= 5% THD (Non-linear Load) |
Frequency Range (Synchronized Range) | 46~54 Hz or 56~64 Hz |
EFFICIENCY | |
Battery Mode | 0.91 |
AC Mode | 0.93 |
BATTERY | |
Long-run Model : Battery Type | Depending on the capacity of external batteries |
Long-run Model : Charging Current (max.) | 1A/2A/4A/6A (Adjustable, 6A is only available for 16pcs batteries) |
Long-run Model : Charging Voltage | 273 VDC ± 1% (Based on 20pcs batteries) |
Long-run Model : Numbers | 16~20 (Adjustable) |
Standard Model : Battery Type | 12 V / 9 Ah |
Standard Model : Charging Current (max.) | 1A/2A |
Standard Model : Charging Voltage | 218.4 VDC ± 1%, 273 VDC ± 1% |
Standard Model : Numbers | 16, 20 |
Standard Model : Typical Recharge Time | 9 hours recover to 90% capacity |
INDICATORS | |
LCD | Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators |
ALARM | |
Battery Mode | Sounding every 4 seconds |
Low Battery | Sounding every second |
Overload | Sounding twice every second |
Fault | Continuously sounding |
ENVIRONMENT | |
Operating Humidity | 0~95% RH @ 0- 40°C (non-condensing) |
Noise Level | Less than 58dB @ 1 Meter |
PHYSICAL | |
Standard Model : Dimension, D x W x H (mm) | 442 x 190 x 688 |
Standard Model : Net Weight (kgs) | 66, 76 |
Long-run Model : Dimension, D x W x H (mm) | 442 x 190 x 318 |
Long-run Model : Net Weight (kgs) | 16 |
MANAGEMENT | |
Optional SNMP | Power management from SNMP manager and web browser |
Smart RS-232/USB | Supports Windows 2000/2003/XP/Vista/2008, Windows 7/8/10, Linux, and MAC |
Reviews
There are no reviews yet.