Mercury Online HP960C-S 0.8PF 6KVA/4.8KW 1/1 Phase Ups Specifications and details
The advanced design of the Mercury online UPS range gives them the performance edge that you expect. Here’s more on the features you will expect from the Mercury 6KVA Online UPS:
- Application: Small network, servers and other IT equipment
- High frequency and double conversion on-line technology
- Fully digitized microprocessor control
- Wide input voltage range
- UPS startup without battery
- Cold start
- Advanced battery management
- Advanced battery charge in UPS off mode
- Lightning and surge protection
- Short circuit and surge protection
- Fan speed auto control when loads varies
- Optional extension battery pack
- Load capacity display
- Smart RS232 communication with monitoring software
- Optional SNMP Card slot
Specifications
Power | 6KVA / 4200W |
Voltage range | 176 ±5VAC~276 ±5VAC |
Frequency | 46~54Hz ±0.5Hz, or 56~64Hz ±0.5Hz auto sensing |
Input phase | Single phase |
Power factor | ≥0.98 |
Voltage range | 220VAC ±1% |
Output phase | Single phase |
Frequency | 50Hz ±0.2% (battery mode) |
THD | < 2% (Linear load); < 6% (non-Linear load) |
Overload | 105%~130% 10min turn to Bypass mode, > 130% 1s turn to Bypass mode |
Crest factor | 3:1 (max) |
Waveform | Pure sine wave |
Transfer time | 0ms (AC mode – Battery mode) 0ms (AC mode – Bypass mode) |
Efficiency | ≥88% |
AC mode | 5 cycles turn off inverter, no transfer to Bypass, provide alarm. |
Battery mode | 5 cycles turn off inverter, provide alarm. |
Bypass mode | Input fuse blown or break action. |
Battery Model | 12V sealed lead acid maintenance free |
DC voltage | 240VDC |
Configuration | 20x 12V/8.2AH |
Backup time | 20min (half load) / 7min (full load) |
Charge current | 1A (standard unit) / 5A (long time unit) |
Recharge time | 90% capacity after 8hrs charging |
Communication Interface | RS232; SNMP (optional) |
Parallel Port | Parallel availability for redundancy and load sharing up to three unit |
LCD Indication | Input voltage/frequency; battery voltage; output voltage/frequency; load watt/VA value & percent; inverter temperature; operation mode such as “on batt” or “on bypass” |
LED Indication | Green: normal operation; Yellow: warning condition Red: abnormal operation |
Noise level | ≤ 55dB |
Temperature | 0~40˚C; 0 ~ 40˚C (storage temperature) |
Humidity | 0~95% (non-condensing) |
Altitude | < 1500m |
Weight Net/Gross | 89/104kg (standard unit); 34/48kg (long time unit) |
Dimension (WxDxH) | 270 x 570 x 720mm |
Packaging (WxDxH) | 370 x 670 x 940mm |
Reviews
There are no reviews yet.