SECOLINK INTRUDER ALARM PANEL PAS SERIES SPECIFICATIONS AND DETAILS
Overview
Currently, these models are being manufactured: PAS808M, PAS816, PAS832, P16, P32, P64  that control 8, 16, 32, 64 intrusion detection sensors (zones), respectively. Secolink Intruder alarm panel models can protect up to 4 partitions (areas) and, depending on the model of the panel, (minus panels) can be controlled by 5 or up to 31 users.
More technical information can be found by clicking on the left side menu bar “Control panels”. Secolink Intruder alarm panel Performs all necessary functions and is suited for the protection of apartments and offices. This control panel is supplemented with a function of calling user’s phone. More technical information can be found in the table below.
Technical Specification
Features | PAS808M | PAS816 | PAS832 |
Alarm system concept | Wired modular system | Wired modular system | Wired modular system |
On-board wired zones | 8 | 8/16 (doubling) | 8/16 (doubling) |
2-wire smoke detector input | – | – | – |
On-board wireless zones | – | – | – |
Maximum zones in system | 8 | 16 | 32 |
On-board PGM | 3 | 3 | 3 |
Maximum PGM in system | 8 | 16 | 16 |
User + installer codes | 5+1 | 31+1 | 31+1 |
Duress code | X1, X2, X3, X4 (when X4 = X4 + 1) | ||
Defaulting user code | Yes | Yes | Yes |
Key switch zone | – | Yes | Yes |
Partitions | 4 | 4 | 4 |
“Shared” partition (common area) | – | Yes | Yes |
System timers | – | 16 | 16 |
Maximum keypads/modules in system | 7 | 15 | 15 |
Event log buffer | 512 | 512 | 512 |
PSTN communicator | In-built | In-built | In-built |
In-built interface for backup communicator | TTL Serial | TTL Serial | TTL Serial |
Data bus protocol | KRBUS | KRBUS | KRBUS |
Total phone numbers: CMS reporting + personal dialing | 4 | 4 | 4 |
Maximum phone numbers for personal dialing | Up to 4 | Up to 4 | Up to 4 |
Maximum phone numbers for CMS reporting | Up to 4 | Up to 4 | Up to 4 |
Reporting protocol | Contact ID | Contact ID, 4×2 | Contact ID, 4×2 |
Voice guide for system control over PSTN | – | PAS816 V3 only | PAS832 V3 only |
Voice guide for system programming over PSTN | – | PAS816 V3 only | PAS816 V3 only |
“Roller” detector type | – | Yes | Yes |
“Vibration” detector type | Yes | Yes | Yes |
“Vibration” zone speed (sensitivity) | 0.01 – 0.25 sec. | 0.01 – 0.25 sec. | 0.01 – 0.25 sec. |
Normal zone speed (sensitivity) | 0.1 – 2.5 sec. | 0.1 – 2.5 sec. | 0.1 – 2.5 sec. |
Zone loop (detector) type | NC, NO, NC/EOL, NO/EOL, NC/DEOL, NO/DEOL, Vibration | NC, NO, NC/EOL, NO/EOL, NC/DEOL, NO/DEOL, Vibration, Roller | |
Arming mode | Away, Max Away, Night, Stay. | ||
Zone definition | Entry/exit, entry/exit forced, interior, interior night armed, follower, interior night follower, perimeter, instant, PGM control; 24h: burglary, panic silent, panic audible, tamper, fire, smoke, fire button, medical button, fire supervisory, low water level, RF Jam, gas detected, water leakage, high temperature, low temperature | ||
Zone attributes | Enable bypass, no alarm, arm when door is closed, entry route, exit route, fire verification, limitation of alarms, limitation of reporting, pre-alarm | Enable bypass, no alarm, arm when door is closed, entry route, exit route, fire verification, limitation of alarms, limitation of reporting, pre-alarm, armed night | |
PGM definition | Fire alarm, fire/burglary alarm, burglary alarm, tamper alarm, technical alarm, selected alarms, chime, zone violation, bypass status, selected trouble, exit/entry warning, exit/arm status, full arm status, power supply, resettable power supply, fire power supply, timer, mono/bi switch | ||
PGM attributes | Inversion, pulsation, latch, pre-alarm, arm notification, arming failure notification, disarm notification, clear alarm notification | ||
Rated voltage of power supply (AC) | ~20 V | ~20 V | ~20 V |
Minimum AC voltage (note: ~16 V input voltage lets control panel to generate max 0.7 A output current) | ~16 V | ~16 V | ~16 V |
Maximum AC voltage (Note: higher than ~22 V voltage can damage control panel) | ~22 V | ~22 V | ~22 V |
Maximum long term output current of control panel (I+AUX + I+BELL + I+PGM + battery charge): | ?1.2 A | ?1.5 A | ?1.5 A |
Maximum current of slow blowing fuse used in primary AC | 250 mA | 250 mA | 250 mA |
Maximum AC power consumption | 150 mA | 150 mA | 150 mA |
Minimum voltage on +AUX, +BELL, +PGM outputs | 12 V | 12 V | 12 V |
Maximum voltage on +AUX, +BELL, +PGM outputs | 13.9 V | 13.9 V | 13.9 V |
Maximum current out of +AUX | +0.8 A | +1 A | +1 A |
Maximum current out of +BELL | +0.8 A | +2 A | +2 A |
Maximum current into -PGM | -0.05 A | -0.05 A | -0.05 A |
Maximum current out of +PGM | +0.8 A | +0.9 A | +0.9 A |
Short circuit, overload protection of +BELL, +PGM, +AUX | Electronic | Electronic | Electronic |
Battery charge, +BELL, +AUX current measurement | – | Yes | Yes |
Failed (waste) backup battery disconnection | – | Yes | Yes |
Maximum battery charging current | +0.4 A | +0.4 A | +0.4 A |
Maximum current of fast blowing fuse used in battery circuit | 3.15 A | 3.15 A | 3.15 A |
Control panel disconnect battery when itÂ’s voltage less than | 9.5 V | 9.5 V | 9.5 V |
Recommended backup battery | 12 V, 7 Ah / 20 Hr | 12 V, 7 Ah / 20 Hr | 12 V, 7 Ah / 20 Hr |
Operational compliance | +EN50131, Grade2 | +EN50131, Grade2 | +EN50131, Grade2 |
Overall dimensions W x H in mm | 145 x 77 | 145 x 77 | 145 x 77 |
Environmental compliance | ROHS | ROHS | ROHS |
Operating temperature | -10oC up to +50oC | ||
Production status | In production | V2 discontinued, V3 in production | V2 discontinued, V3 in production |
Latest firmware version | v0.03 | Â | Â |