GIGANET GN-UIC80L 8kVA/6.4kW Three Phase Online UPS
The GIGANET GN-UIC80L is a reliable 8 kVA / 6.4 kW three phase online UPS designed to deliver clean, stable, and uninterrupted power for small to mid sized installations. Employing true double conversion technology, the GN-UIC80L continuously regulates incoming mains power and outputs a pure sine wave current — protecting your sensitive electronics from blackouts, voltage spikes, surges, brownouts, and grid instability.
This UPS is ideal for setups such as small server rooms, network closets, branch office infrastructures, light industrial systems, or other medium demand environments where power consistency matters. The three phase input and output allows for balanced power delivery and efficient load handling, even where the load is moderate but consistent.
Features |
| True online double conversion design |
| Build-in input and output transformer with strong galvanic isolation |
| Wide input range, avoid frequently transfer to battery mode, prolong the battery lifetime |
| With parallel function, flexibly response to the expansion and redun- dancy requirement |
| Intelligent battery management technology, fully protect battery |
| Battery cold start function |
| Comprehensive and reliable protection |
Specifications
| Model | GN-UIC60L | GN-UIC80L | GN-UIC100L | GN-UIC150L | GN-UIC200L | GN-UIC300L | GN-UIC400L |
| Capacity VA/Watts | 6kVA/4.8kW | 8kVA/6.4kW | 10kVA/8kW | 15kVA/12kW | 20kVA/16kW | 30kVA/24kW | 40kVA/32kW |
| INPUT | |||||||
| Operating Voltage Range | 380Vac(±20%), (3Ph+N+PE) | ||||||
| Operating Frequency Range | 50/60Hz (±5%) | ||||||
| Power Factor | >0.97 (with filter) | ||||||
| Max.Input Current(A) | 14 | 18 | 23 | 34 | 45 | 68 | 90 |
| OUTPUT | |||||||
| Output Voltage | 220Vac(1±1%) | ||||||
| Output frequency | 50/60Hz(1±1%) | ||||||
| Crest factor | 3:1(max) | ||||||
| Efficiency | 6~8KVA: 85% online 10~40KVA: 90% online | ||||||
| Harmonic Distortion (THDv) | <1.5% with linear load | ||||||
| BATTERY | |||||||
| Battery voltage | 192Vdc | 240Vdc | |||||
| SYSTEM FEATURES | |||||||
| Transfer time | Utility Battery : Oms | ||||||
| Overload | Load≤125%/ 1min; ≤150% /200ms,to Bypass | ||||||
| LED display | Battery low, Mains status, Inverter, Bypass, UPS failure, Overload | ||||||
| LCD display | I/O voltage, Frequency, Battery voltage, Load percentage,Internal temperature | ||||||
| Communication Interface | RS232, SNMP (optional), Dry contact,RS485 | ||||||
| PHYSICAL | |||||||
| Dimension W×D×H (mm) | 305*585*864 | 409*798**1044 | 555*741*1200 | 600*800*1200 | |||
| Net Weight(48V/192V)(kg) | 100 | 110 | 120 | 145 | 155 | 255 | 336 |
| ENVIRONMENT | |||||||
| Operating Temperature | 0~40°C | ||||||
| Storage Temperature | -25℃~55℃ | ||||||
| Humidity Range | 0~95% (Non-condensing) | ||||||
| Altitude | <1500m | ||||||
| Noise level | <55dB | ||||||
| STANDARDS | |||||||
| Safety | IEC/EN62040-1 ;IEC/EN60950-1 | ||||||
| EMC | IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4, IEC61000-4-5,IEC61000-4-6,IEC61000-4-8 | ||||||






Reviews
There are no reviews yet.